New site with nortec replacement cylinders
Nortec Canister products
HVAC Online
Sunday, July 17, 2011
Friday, April 1, 2011
HD 100 Hot Dawg Power Vented - CFM 1,490 - BTU 100,000 - Aluminized - Propeller Unit
It's a low-profile gas-fired unit heater that is designed to heat your work space. It is certified for residential, commercial, and industrial use.
Heat Exchanger Material - Aluminized
Propeller Unit
• Hush-puppy quiet operation
• Uses natural or propane gas
• Certified for residential, commercial and industrial use.
• Low-profile design and neutral color to blend in with decor.
• Lightweight, easily installs 1" from ceiling with only 2 angle brackets (included on sizes 30-75, accessory for 100, 125).
• Install quickly and easily with field wiring connections and knockouts for quick access to gas and electricity.
• Standard power exhaust simplifies side-wall or roof venting with small-diameter vent pipe.
• Right or left hand controls available on all 30-75 units. Gas, electrical and flue connections can be changed by simply flipping the Hot Dawg over.
• Permanently-lubricated motor for trouble-free dependability.
• Full 10-year warranty on heat exchanger.
• Also available with a blower. Contact HVAC Online for further information.
Unit | Btu/Hr Input | Application |
HD/HDS 30 | 30,000 | 1 to 1-1/2 Car Garage |
HD/HDS 45 | 45,000 | 2 to 2-1/2 Car Garage |
HD/HDS 60 | 60,000 | 3 to 3-1/2 Car Garage |
HD/HDS 75, 100, 125 | 75,000 - 125,000 | Large Garage, Commercial / Industrial Space |
Purchase One Now!
View the Hot Dawg specification brochure
View the Hot Dawg submittal
HD 100 Hot Dawg Power Vented - CFM 1,490 - BTU 100,000 - Stainless Steel - Propeller Unit
It's a low-profile gas-fired unit heater that is designed to heat your work space. It is certified for residential, commercial, and industrial use.
Heat Exchanger Material - Stainless Steel
Propeller Unit
• Hush-puppy quiet operation
• Uses natural or propane gas
• Certified for residential, commercial and industrial use.
• Low-profile design and neutral color to blend in with decor.
• Lightweight, easily installs 1" from ceiling with only 2 angle brackets (included on sizes 30-75, accessory for 100, 125).
• Install quickly and easily with field wiring connections and knockouts for quick access to gas and electricity.
• Standard power exhaust simplifies side-wall or roof venting with small-diameter vent pipe.
• Right or left hand controls available on all 30-75 units. Gas, electrical and flue connections can be changed by simply flipping the Hot Dawg over.
• Permanently-lubricated motor for trouble-free dependability.
• Full 10-year warranty on heat exchanger.
• Also available with a blower. Contact HVAC Online for further information.
Unit | Btu/Hr Input | Application |
HD/HDS 30 | 30,000 | 1 to 1-1/2 Car Garage |
HD/HDS 45 | 45,000 | 2 to 2-1/2 Car Garage |
HD/HDS 60 | 60,000 | 3 to 3-1/2 Car Garage |
HD/HDS 75, 100, 125 | 75,000 - 125,000 | Large Garage, Commercial / Industrial Space |
Purchase One Now!
View the Hot Dawg specification brochureView the Hot Dawg submittal
Wednesday, March 2, 2011
Nu-Air heat recovery ventilation system
ES100 - residential HRV/ERV
[ES100]
$730.00
ES100 - residential HRV/ERV
Add item to cart to get shipping estimate.
* 90 – 176 cfm (2000 – 3500 sqft)
* Energy Star Compliant HRV
* Uncluttered lightweight aluminum cabinet (29”x19”x16”), 45 lbs
* Side port configuration
* Aluminum crossflow core
* Service friendly (replace any major part in less than 10 minutes)
* Simple electronic balancing, no dampers needed and no over ventilation
* Intelligent defrost system adjusts to outdoor temperature [Proportional Defrost]
* Drain, hanger kit and polyester filters included
* Unit: 5 year warranty; Core: lifetime warranty
ES Series Controls
ES-T1: 20-40-60-Minute Timer
This timer is used to make the unit operate in high speed for 20, 40 or 60 minutes and is typically installed in bathrooms, kitchens and workspaces. You may toggle between functions or even cancel a high speed run by tapping the touch pad. The ES-T1 will initiate timed high speed ventilation when the unit is in Standby mode from another control or a jumper wire installed on the HRV control board. Use 4-conductor wire.
ES-M1: OFF STBY Lo Hi
This basic control allows you to select from standby mode, during which another control may initiate
operation, full-time low speed, or full-time high speed. The ES-M1 is ideal for installations where basic
ventilation functions are required or desired, especially in buildings with intermittent occupation. Use 4-
conductor wire.
ES-M2: OFF STBY Lo 20 Lo/40 STBY
While featuring the convenience of full-time standby and full-time low speed modes, the ES-M2 offers the
additional ability to ventilate in low speed for 20 minutes and then switch to standby for 40 minutes. This
control is perfect to use when you leave home and require just a little bit of ventilation to make your home
fresh when you return. Use 4-conductor wire.
ES-M3: OFF STBY Lo 20 Lo/40 RECIRC.
Because ES Series units are equipped with a recirculation system that will not recycle bathroom air, the ESM3 control is just right for people who have secondary heating and cooling equipment, such as wood stoves or room air conditioners. The re-circulation function of the ES-M3 enables you to re-circulate air for 40 minutes of every hour from a heated or cooled space within your home, helping to alleviate the problem of super-heated or super-cooled rooms. Use 4-conductor wire.
Before You Buy ... Compare Us To The Competition
Nu-Air’s unique perspective, values and sizeable long-term investments in research and development have enabled it to build innovation into every aspect of every unit. Nu-Air innovations include:
Precise dampering controls
Precise dampering controls enable Nu-Air to eliminate the over and under ventilation problems that are common and persistent, especially in high rise buildings. Over and under ventilation problems are commonly reported with other integrated units available in the marketplace, and especially prevalent when contractors are forced to integrate components from different vendors on-site. The problems reported in these situations become even more extreme in the high rise market. Nu-Air units:
* Prevent over-ventilation, which is a major problem with competitor products because they do not have precise control over exhaust and fresh air volumes, which increases operating costs and reduces comfort; and/or
* Prevent limited ventilation, by using large HRV cores and fully integrating all elements of each unit, improving comfort and energy efficiency.
Enhanced energy efficiency
Enhanced energy efficiency due to the fact that Nu-Air utilizes a:
* Highly energy efficiency motor, which can reduce total household energy consumption by 25%, according to a CMHC study on Electronically Commutated Motors (ECM);
* Unique damper system allows for the unit to automatically defrost during the heat cycle using the same single fan. Competitor units require a separate call for heat which uses heat unnecessarily; and
* Large sized core which reduces fan noise to a minimum, increases the efficiency of heat recovery, and reduces power consumption. Each being a significant benefit relative to Nu-Air’s competition.
Easy installation
Easy installation prevents problems and reduces on-site labour costs by:
* Making hook-up points easy to see and access;
* Enabling tool-free and self-explanatory hook-ups; and
* Using either traditional duct work or the increasingly common new standard, high velocity (or high pressure) duct systems.
Reduced unit weight
Reduced unit weight, half that of the closest competitor, reduces costs by:
* Limiting on-site labour to one person rather than two, enabling installers to save as much as $400 of on-site labour per unit (thanks also to Nu-Air’s easy installation); and
* Cutting shipping costs.
Multi-Purposed Equipment
All equipment within each unit is multi-purposed by integrating functionality in a manner that achieves multi-use of components. For example, new Electronically Commutated Motors (ECM) allow for infinitely variable air flow between 100 – 1,000 cubic feet per minute (cfm), enabling one motor to be used for both HRV (@100 cfm) and heat (@1,000 cfm).
Efficient, effective and reliable – Once you compare you will know why Nu-Air is a ventilation industry leader
[ES100]
$730.00
ES100 - residential HRV/ERV
Add item to cart to get shipping estimate.
* 90 – 176 cfm (2000 – 3500 sqft)
* Energy Star Compliant HRV
* Uncluttered lightweight aluminum cabinet (29”x19”x16”), 45 lbs
* Side port configuration
* Aluminum crossflow core
* Service friendly (replace any major part in less than 10 minutes)
* Simple electronic balancing, no dampers needed and no over ventilation
* Intelligent defrost system adjusts to outdoor temperature [Proportional Defrost]
* Drain, hanger kit and polyester filters included
* Unit: 5 year warranty; Core: lifetime warranty
ES Series Controls
ES-T1: 20-40-60-Minute Timer
This timer is used to make the unit operate in high speed for 20, 40 or 60 minutes and is typically installed in bathrooms, kitchens and workspaces. You may toggle between functions or even cancel a high speed run by tapping the touch pad. The ES-T1 will initiate timed high speed ventilation when the unit is in Standby mode from another control or a jumper wire installed on the HRV control board. Use 4-conductor wire.
ES-M1: OFF STBY Lo Hi
This basic control allows you to select from standby mode, during which another control may initiate
operation, full-time low speed, or full-time high speed. The ES-M1 is ideal for installations where basic
ventilation functions are required or desired, especially in buildings with intermittent occupation. Use 4-
conductor wire.
ES-M2: OFF STBY Lo 20 Lo/40 STBY
While featuring the convenience of full-time standby and full-time low speed modes, the ES-M2 offers the
additional ability to ventilate in low speed for 20 minutes and then switch to standby for 40 minutes. This
control is perfect to use when you leave home and require just a little bit of ventilation to make your home
fresh when you return. Use 4-conductor wire.
ES-M3: OFF STBY Lo 20 Lo/40 RECIRC.
Because ES Series units are equipped with a recirculation system that will not recycle bathroom air, the ESM3 control is just right for people who have secondary heating and cooling equipment, such as wood stoves or room air conditioners. The re-circulation function of the ES-M3 enables you to re-circulate air for 40 minutes of every hour from a heated or cooled space within your home, helping to alleviate the problem of super-heated or super-cooled rooms. Use 4-conductor wire.
Before You Buy ... Compare Us To The Competition
Nu-Air’s unique perspective, values and sizeable long-term investments in research and development have enabled it to build innovation into every aspect of every unit. Nu-Air innovations include:
Precise dampering controls
Precise dampering controls enable Nu-Air to eliminate the over and under ventilation problems that are common and persistent, especially in high rise buildings. Over and under ventilation problems are commonly reported with other integrated units available in the marketplace, and especially prevalent when contractors are forced to integrate components from different vendors on-site. The problems reported in these situations become even more extreme in the high rise market. Nu-Air units:
* Prevent over-ventilation, which is a major problem with competitor products because they do not have precise control over exhaust and fresh air volumes, which increases operating costs and reduces comfort; and/or
* Prevent limited ventilation, by using large HRV cores and fully integrating all elements of each unit, improving comfort and energy efficiency.
Enhanced energy efficiency
Enhanced energy efficiency due to the fact that Nu-Air utilizes a:
* Highly energy efficiency motor, which can reduce total household energy consumption by 25%, according to a CMHC study on Electronically Commutated Motors (ECM);
* Unique damper system allows for the unit to automatically defrost during the heat cycle using the same single fan. Competitor units require a separate call for heat which uses heat unnecessarily; and
* Large sized core which reduces fan noise to a minimum, increases the efficiency of heat recovery, and reduces power consumption. Each being a significant benefit relative to Nu-Air’s competition.
Easy installation
Easy installation prevents problems and reduces on-site labour costs by:
* Making hook-up points easy to see and access;
* Enabling tool-free and self-explanatory hook-ups; and
* Using either traditional duct work or the increasingly common new standard, high velocity (or high pressure) duct systems.
Reduced unit weight
Reduced unit weight, half that of the closest competitor, reduces costs by:
* Limiting on-site labour to one person rather than two, enabling installers to save as much as $400 of on-site labour per unit (thanks also to Nu-Air’s easy installation); and
* Cutting shipping costs.
Multi-Purposed Equipment
All equipment within each unit is multi-purposed by integrating functionality in a manner that achieves multi-use of components. For example, new Electronically Commutated Motors (ECM) allow for infinitely variable air flow between 100 – 1,000 cubic feet per minute (cfm), enabling one motor to be used for both HRV (@100 cfm) and heat (@1,000 cfm).
Efficient, effective and reliable – Once you compare you will know why Nu-Air is a ventilation industry leader
Monday, February 7, 2011
Rittling Gas Unit Heaters
Full line of Rittling Gas Unit and Cabinet Unit Heaters
Steam and Hot water
Fan Coils
From the finest architectural enclosures to heavy-duty security
enclosures, Rittling offers the largest selection of hydronic heating
equipment available for your commercial, institutional and industrial
applications. This enormous selection, combined with unmatched
quality and durability, make Rittling the premium source for all
your hydronic heating needs.
Cabinet Unit Heaters
Fan Coils
Unit Heaters
Steam and Hot water
Fan Coils
From the finest architectural enclosures to heavy-duty security
enclosures, Rittling offers the largest selection of hydronic heating
equipment available for your commercial, institutional and industrial
applications. This enormous selection, combined with unmatched
quality and durability, make Rittling the premium source for all
your hydronic heating needs.
Cabinet Unit Heaters
Fan Coils
Unit Heaters
Monday, November 8, 2010
HVAC Online
Northrich Home Page
HVAC Online - online store with many heating and cooling products, including Rittling Unit Heaters, Hot Dawg Gas Heater, Danfoss VFD Variable Frequency Drive.
Danfoss VFD VAriable Frequency Drive
VFD Variable Frequency Drive
Unit Heaters and Cabinet Unit Heaters
Rittling Unit Heaters
Modine Gas Unit Heaters
Hot Dawg Garage Heaters
Hot Dawg Gas Unit Heater
Fan Coil Heating and Cooling
Danfoss VFD Drive
HD 100 Hot Dawg Power Vented - CFM 1,490 - BTU 100,000 - Aluminized - Propeller Unit
HD 100 Hot Dawg Power Vented - CFM 1,490 - BTU 100,000 - Stainless Steel - Propeller Unit
HD 75 Hot Dawg Power Vented - CFM 1,160 - BTU 75,000 - Aluminized - Propeller Unit
HD 75 Hot Dawg Power Vented - CFM 1,160 - BTU 75,000 - Stainless Steel - Propeller Unit
HDB 100 Hot Dawg Power Vented - CFM nominal 1,060 - BTU 100,000 - Aluminized - Blower Unit - HP 1/2
HDB 100 Hot Dawg Power Vented - CFM nominal 1,060 - BTU 100,000 - Stainless Steel - Blower Unit - HP 1/2
HD 125 Hot Dawg Power Vented - CFM 1,980 - BTU 125,000 - Aluminized - Propeller Unit
HD 125 Hot Dawg Power Vented - CFM 1,980 - BTU 125,000 - Stainless Steel - Propeller Unit
HD 30 Hot Dawg Power Vented - CFM 505 - BTU 30,000 - Aluminized - Propeller Unit
HD 30 Hot Dawg Power Vented - CFM 505 - BTU 30,000 - Stainless Steel - Propeller Unit
HD 45 Hot Dawg Power Vented - CFM 720 - BTU 45,000 - Aluminized - Propeller Unit
HD 45 Hot Dawg Power Vented - CFM 720 - BTU 45,000 - Stainless Steel - Propeller Unit
HD 60 Hot Dawg Power Vented - CFM - BTU 990 - Aluminized - Propeller Unit
HD 60 Hot Dawg Power Vented - CFM 990 - BTU 60,000 - Stainless Steel - Propeller Unit
HDB 125 Hot Dawg Power Vented - CFM nominal 1,240 - BTU 125,000 - Aluminized - Blower Unit - HP 1/2
HDB 125 Hot Dawg Power Vented - CFM nominal 1,240 - BTU 125,000 - Stainless Steel - Blower Unit - HP 1/2
HDB 60 Hot Dawg Power Vented - CFM nominal 635 - BTU 60,000 - Aluminized - Blower Unit - HP 1/4
HDB 60 Hot Dawg Power Vented - CFM nominal 635 - BTU 60,000 - Stainless Steel - Blower Unit - HP 1/4
HDB 75 Hot Dawg Power Vented - CFM nominal 795 - BTU 45,000 - Aluminized - Blower Unit - HP 1/3
HDB 75 Hot Dawg Power Vented - CFM nominal 795 - BTU 45,000 - Stainless Steel - Blower Unit - HP 1/3
Rittling RF-200-02 Cabinet Unit heater - 200 nominal CFM
Rittling RF-200-03 Cabinet Unit heater - 230 nominal CFM
Rittling RF-200-04 Cabinet Unit heater - 335 nominal CFM
Rittling RF-200-06 Cabinet Unit heater - 435 nominal CFM
Rittling RFRC-420-02 Cabinet Unit heater - 200 nominal CFM
Rittling RFRC-420-03 Cabinet Unit heater - 230 nominal CFM
Rittling RFRC-420-04 Cabinet Unit heater - 335 nominal CFM
Rittling RFRC-420-06 Cabinet Unit heater - 435 nominal CFM
Rittling FCHP-500-02 Fan Coil - 150 nominal CFM
Rittling FCHP-500-03 Fan Coil - 215 nominal CFM
Rittling FCHP-500-04 Fan Coil - 275 nominal CFM
Rittling FCHP-500-06 Fan Coil - 390 nominal CFM
Rittling FF-200-02 Fan Coil - 150 nominal CFM
Rittling FF-200-03 Fan Coil - 215 nominal CFM
Rittling FF-200-04 Fan Coil - 275 nominal CFM
Rittling FF-200-06 Fan Coil - 390 nominal CFM
Rittling RH-108 Horizontal Unit Heater - 1550 nominal CFM
Rittling RH-121 Horizontal Unit Heater - 1775 nominal CFM
Rittling RH-165 Horizontal Unit Heater - 2500 nominal CFM
Rittling RH-18 Horizontal Unit Heater - 400 nominal CFM
Rittling RH-193 Horizontal Unit Heater - 2900 nominal CFM
Rittling RH-24 Horizontal Unit Heater - 450 nominal CFM
Rittling RH-258 Horizontal Unit Heater - 3900 nominal CFM
Rittling RH-290 Horizontal Unit Heater - 4300 nominal CFM
Rittling RH-33 Horizontal Unit Heater - 630 nominal CFM
Rittling RH-340 Horizontal Unit Heater - 5130 nominal CFM
Rittling RH-47 Horizontal Unit Heater - 730 nominal CFM
Rittling RH-63 Horizontal Unit Heater - 1120 nominal CFM
Rittling RH-86 Horizontal Unit Heater - 1340 nominal CFM
Rittling RV-139 Vertical Unit Heater - 2500 nominal CFM
Rittling RV-161 Vertical Unit Heater - 2900 nominal CFM
Rittling RV-193 Vertical Unit Heater - 3900 nominal CFM
Rittling RV-212 Vertical Unit Heater - 4300 nominal CFM
Rittling RV-247 Vertical Unit Heater - 5130 nominla CFM
Rittling RV-279 Vertical Unit Heater - 5800 nominal CFM
Rittling RV-333 Vertical Unit Heater - 6600 nominal CFM
Rittling RV-385 Vertical Unit Heater - 7860 nominal CFM
Rittling RV-42 Vertical Unit Heater - 950 nominal CFM
Rittling RV-500 Vertical Unit Heater - 10790 nominal CFM
Rittling RV-59 Vertical Unit Heater - 1150 nominal CFM
Rittling RV-610 Vertical Unit Heater - 12350 nominal CFM
Rittling RV-78 Vertical Unit Heater - 1550 nominal CFM
Rittling RV-95 Vertical Unit Heater - 1775 nominal CFM
0.5 (1/2) HP Danfoss VFD - VLT2800 208-230v-1 or 3 Phase input
0.75 (3/4) HP Danfoss VFD - VLT2800 208-230v-1 or 3 Phase input
0.75 (3/4) HP Danfoss VFD - VLT2800 460v-3 Phase
1.0 HP Danfoss VFD - VLT2800 208-230v-1 or 3 Phase input
1.0 HP Danfoss VFD - VLT2800 460v-3 Phase
1.5 HP Danfoss VFD - VLT2800 208-230v-1 or 3 Phase input
1.5 HP Danfoss VFD - VLT2800 460v-3 Phase
10 HP Danfoss VFD - VLT2800 460v-3 Phase
15 HP Danfoss VFD - VLT2800 460v-3 Phase
2.0 HP Danfoss VFD - VLT2800 208-230v-1 or 3 Phase input
2.0 HP Danfoss VFD - VLT2800 460v-3 Phase
20 HP Danfoss VFD - VLT2800 460v-3 Phase
20 HP Danfoss VFD - VLT2800 460v-3 Phase
25 HP Danfoss VFD - VLT2800 460v-3 Phase
3.0 HP Danfoss VFD - VLT2800 208-230v-3 Phase
3.0 HP Danfoss VFD - VLT2800 230v-1 Phase input
3.0 HP Danfoss VFD - VLT2800 460v-3 Phase
5.0 HP Danfoss VFD - VLT2800 208-230v-3 Phase
5.0 HP Danfoss VFD - VLT2800 230v-1 Phase input
5.0 HP Danfoss VFD - VLT2800 460v-3 Phase
7.5 HP Danfoss VFD - VLT2800 460v-3 Phase
0.25 (1/4) HP Danfoss VFD - VLT Micro 230v-1p input
0.33 (1/3) HP Danfoss VFD - VLT Micro 230v-3p
0.5 (1/2) HP Danfoss VFD - VLT Micro 230v-1p input
0.5 (1/2) HP Danfoss VFD - VLT Micro 230v-3p
0.5 (1/2) HP Danfoss VFD - VLT Micro 480v-3p
1.0 HP Danfoss VFD - VLT Micro 230v-1p input
1.0 HP Danfoss VFD - VLT Micro 230v-3p
1.0 HP Danfoss VFD - VLT Micro 480v-3p
10.0 HP Danfoss VFD - VLT Micro 480v-3p
2.0 HP Danfoss VFD - VLT Micro 230v-1p input
2.0 HP Danfoss VFD - VLT Micro 230v-3p
2.0 HP Danfoss VFD - VLT Micro 480v-3p
3.0 HP Danfoss VFD - VLT Micro 230v-1p input
3.0 HP Danfoss VFD - VLT Micro 230v-3p
3.0 HP Danfoss VFD - VLT Micro 480v-3p
4.0 HP Danfoss VFD - VLT Micro 480v-3p
5.0 HP Danfoss VFD - VLT Micro 230v-3p
5.0 HP Danfoss VFD - VLT Micro 480v-3p
7.5 HP Danfoss VFD - VLT Micro 480v-3p
HVAC Online - online store with many heating and cooling products, including Rittling Unit Heaters, Hot Dawg Gas Heater, Danfoss VFD Variable Frequency Drive.
Danfoss VFD VAriable Frequency Drive
VFD Variable Frequency Drive
Unit Heaters and Cabinet Unit Heaters
Rittling Unit Heaters
Modine Gas Unit Heaters
Hot Dawg Garage Heaters
Hot Dawg Gas Unit Heater
Fan Coil Heating and Cooling
Danfoss VFD Drive
HD 100 Hot Dawg Power Vented - CFM 1,490 - BTU 100,000 - Aluminized - Propeller Unit
HD 100 Hot Dawg Power Vented - CFM 1,490 - BTU 100,000 - Stainless Steel - Propeller Unit
HD 75 Hot Dawg Power Vented - CFM 1,160 - BTU 75,000 - Aluminized - Propeller Unit
HD 75 Hot Dawg Power Vented - CFM 1,160 - BTU 75,000 - Stainless Steel - Propeller Unit
HDB 100 Hot Dawg Power Vented - CFM nominal 1,060 - BTU 100,000 - Aluminized - Blower Unit - HP 1/2
HDB 100 Hot Dawg Power Vented - CFM nominal 1,060 - BTU 100,000 - Stainless Steel - Blower Unit - HP 1/2
HD 125 Hot Dawg Power Vented - CFM 1,980 - BTU 125,000 - Aluminized - Propeller Unit
HD 125 Hot Dawg Power Vented - CFM 1,980 - BTU 125,000 - Stainless Steel - Propeller Unit
HD 30 Hot Dawg Power Vented - CFM 505 - BTU 30,000 - Aluminized - Propeller Unit
HD 30 Hot Dawg Power Vented - CFM 505 - BTU 30,000 - Stainless Steel - Propeller Unit
HD 45 Hot Dawg Power Vented - CFM 720 - BTU 45,000 - Aluminized - Propeller Unit
HD 45 Hot Dawg Power Vented - CFM 720 - BTU 45,000 - Stainless Steel - Propeller Unit
HD 60 Hot Dawg Power Vented - CFM - BTU 990 - Aluminized - Propeller Unit
HD 60 Hot Dawg Power Vented - CFM 990 - BTU 60,000 - Stainless Steel - Propeller Unit
HDB 125 Hot Dawg Power Vented - CFM nominal 1,240 - BTU 125,000 - Aluminized - Blower Unit - HP 1/2
HDB 125 Hot Dawg Power Vented - CFM nominal 1,240 - BTU 125,000 - Stainless Steel - Blower Unit - HP 1/2
HDB 60 Hot Dawg Power Vented - CFM nominal 635 - BTU 60,000 - Aluminized - Blower Unit - HP 1/4
HDB 60 Hot Dawg Power Vented - CFM nominal 635 - BTU 60,000 - Stainless Steel - Blower Unit - HP 1/4
HDB 75 Hot Dawg Power Vented - CFM nominal 795 - BTU 45,000 - Aluminized - Blower Unit - HP 1/3
HDB 75 Hot Dawg Power Vented - CFM nominal 795 - BTU 45,000 - Stainless Steel - Blower Unit - HP 1/3
Rittling RF-200-02 Cabinet Unit heater - 200 nominal CFM
Rittling RF-200-03 Cabinet Unit heater - 230 nominal CFM
Rittling RF-200-04 Cabinet Unit heater - 335 nominal CFM
Rittling RF-200-06 Cabinet Unit heater - 435 nominal CFM
Rittling RFRC-420-02 Cabinet Unit heater - 200 nominal CFM
Rittling RFRC-420-03 Cabinet Unit heater - 230 nominal CFM
Rittling RFRC-420-04 Cabinet Unit heater - 335 nominal CFM
Rittling RFRC-420-06 Cabinet Unit heater - 435 nominal CFM
Rittling FCHP-500-02 Fan Coil - 150 nominal CFM
Rittling FCHP-500-03 Fan Coil - 215 nominal CFM
Rittling FCHP-500-04 Fan Coil - 275 nominal CFM
Rittling FCHP-500-06 Fan Coil - 390 nominal CFM
Rittling FF-200-02 Fan Coil - 150 nominal CFM
Rittling FF-200-03 Fan Coil - 215 nominal CFM
Rittling FF-200-04 Fan Coil - 275 nominal CFM
Rittling FF-200-06 Fan Coil - 390 nominal CFM
Rittling RH-108 Horizontal Unit Heater - 1550 nominal CFM
Rittling RH-121 Horizontal Unit Heater - 1775 nominal CFM
Rittling RH-165 Horizontal Unit Heater - 2500 nominal CFM
Rittling RH-18 Horizontal Unit Heater - 400 nominal CFM
Rittling RH-193 Horizontal Unit Heater - 2900 nominal CFM
Rittling RH-24 Horizontal Unit Heater - 450 nominal CFM
Rittling RH-258 Horizontal Unit Heater - 3900 nominal CFM
Rittling RH-290 Horizontal Unit Heater - 4300 nominal CFM
Rittling RH-33 Horizontal Unit Heater - 630 nominal CFM
Rittling RH-340 Horizontal Unit Heater - 5130 nominal CFM
Rittling RH-47 Horizontal Unit Heater - 730 nominal CFM
Rittling RH-63 Horizontal Unit Heater - 1120 nominal CFM
Rittling RH-86 Horizontal Unit Heater - 1340 nominal CFM
Rittling RV-139 Vertical Unit Heater - 2500 nominal CFM
Rittling RV-161 Vertical Unit Heater - 2900 nominal CFM
Rittling RV-193 Vertical Unit Heater - 3900 nominal CFM
Rittling RV-212 Vertical Unit Heater - 4300 nominal CFM
Rittling RV-247 Vertical Unit Heater - 5130 nominla CFM
Rittling RV-279 Vertical Unit Heater - 5800 nominal CFM
Rittling RV-333 Vertical Unit Heater - 6600 nominal CFM
Rittling RV-385 Vertical Unit Heater - 7860 nominal CFM
Rittling RV-42 Vertical Unit Heater - 950 nominal CFM
Rittling RV-500 Vertical Unit Heater - 10790 nominal CFM
Rittling RV-59 Vertical Unit Heater - 1150 nominal CFM
Rittling RV-610 Vertical Unit Heater - 12350 nominal CFM
Rittling RV-78 Vertical Unit Heater - 1550 nominal CFM
Rittling RV-95 Vertical Unit Heater - 1775 nominal CFM
0.5 (1/2) HP Danfoss VFD - VLT2800 208-230v-1 or 3 Phase input
0.75 (3/4) HP Danfoss VFD - VLT2800 208-230v-1 or 3 Phase input
0.75 (3/4) HP Danfoss VFD - VLT2800 460v-3 Phase
1.0 HP Danfoss VFD - VLT2800 208-230v-1 or 3 Phase input
1.0 HP Danfoss VFD - VLT2800 460v-3 Phase
1.5 HP Danfoss VFD - VLT2800 208-230v-1 or 3 Phase input
1.5 HP Danfoss VFD - VLT2800 460v-3 Phase
10 HP Danfoss VFD - VLT2800 460v-3 Phase
15 HP Danfoss VFD - VLT2800 460v-3 Phase
2.0 HP Danfoss VFD - VLT2800 208-230v-1 or 3 Phase input
2.0 HP Danfoss VFD - VLT2800 460v-3 Phase
20 HP Danfoss VFD - VLT2800 460v-3 Phase
20 HP Danfoss VFD - VLT2800 460v-3 Phase
25 HP Danfoss VFD - VLT2800 460v-3 Phase
3.0 HP Danfoss VFD - VLT2800 208-230v-3 Phase
3.0 HP Danfoss VFD - VLT2800 230v-1 Phase input
3.0 HP Danfoss VFD - VLT2800 460v-3 Phase
5.0 HP Danfoss VFD - VLT2800 208-230v-3 Phase
5.0 HP Danfoss VFD - VLT2800 230v-1 Phase input
5.0 HP Danfoss VFD - VLT2800 460v-3 Phase
7.5 HP Danfoss VFD - VLT2800 460v-3 Phase
0.25 (1/4) HP Danfoss VFD - VLT Micro 230v-1p input
0.33 (1/3) HP Danfoss VFD - VLT Micro 230v-3p
0.5 (1/2) HP Danfoss VFD - VLT Micro 230v-1p input
0.5 (1/2) HP Danfoss VFD - VLT Micro 230v-3p
0.5 (1/2) HP Danfoss VFD - VLT Micro 480v-3p
1.0 HP Danfoss VFD - VLT Micro 230v-1p input
1.0 HP Danfoss VFD - VLT Micro 230v-3p
1.0 HP Danfoss VFD - VLT Micro 480v-3p
10.0 HP Danfoss VFD - VLT Micro 480v-3p
2.0 HP Danfoss VFD - VLT Micro 230v-1p input
2.0 HP Danfoss VFD - VLT Micro 230v-3p
2.0 HP Danfoss VFD - VLT Micro 480v-3p
3.0 HP Danfoss VFD - VLT Micro 230v-1p input
3.0 HP Danfoss VFD - VLT Micro 230v-3p
3.0 HP Danfoss VFD - VLT Micro 480v-3p
4.0 HP Danfoss VFD - VLT Micro 480v-3p
5.0 HP Danfoss VFD - VLT Micro 230v-3p
5.0 HP Danfoss VFD - VLT Micro 480v-3p
7.5 HP Danfoss VFD - VLT Micro 480v-3p
Subscribe to:
Posts (Atom)